Siplus PS, DC UPS module 24 V/40A, -25...+70°C with conformal coating based on 6EP1931-2FC21. Uninterruptible power supply without interface, input: 24 VDC/43A, output: 24 VDC/40A
AS-i Power 3A, ~120-230 VAC, AS-Interface power supply unit, IP20, input: ~120-230 VAC, output: AS-i, 3A (30 VDC), IP20 with integrated ground fault detection, with integrated overload detection with AS-i data decoupling
AS-i Power 3A, 24 VDC AS-Interface power supply unit, IP20, input: 24 VDC, output: AS-i, 3A (30 VDC), IP20 with integrated ground fault detection, with integrated overload detection with AS-i data decoupling
AS-i Power 2.6A, max. 100 W, ~120-230 VAC, AS-Interface power supply unit, IP20, input: ~120-230 VAC, output: AS-i, 2.6A (30 VDC), limitation of the output power max. 100 W, IP20, with integrated ground fault detection with AS-i data decoupling
AS-i Power 5A, ~120-230 VAC, AS-Interface power supply unit, IP20, input: ~120-230 VAC, output: AS-i, 5A (30 VDC), IP20, with integrated ground fault detection, with integrated overload detection with AS-i data decoupling
AS-i Power 8A, ~120/230-500 VAC, AS-Interface power supply unit, IP20, input: ~120/230-500 VAC, output: AS-i, 8A (30 VDC), with integrated ground fault detection, with integrated overload detection with AS-i data decoupling
PSN130S 3A, ~120-230 VAC, IP20, power supply unit 30 V, for AS-i without AS-i data decoupling, input: ~120-230 VAC, output: 30 VDC, 3 A, IP20, with integrated overload detection with signaling contact
PSN130S 4A, ~120-230 VAC, IP20, power supply unit 30 V, for AS-i without AS-i data decoupling, input: ~120-230 VAC, output: 30 VDC, 4 A, IP20, with integrated overload detection with signaling contact
SN130S 8A, ~120-230 VAC, IP20, power supply unit 30 V, for AS-i without AS-i data decoupling, input: ~120-230 VAC, output: 30 VDC, 8 A, IP20, with integrated overload detection with signaling contact
AS-i data decoupler 1x4A, screw terminals, AS-i single, data decoupling module IP20, SlimLine S22.5, screw terminals, overall width module 22.5 mm, input: 24-30 VDC, output: 1xAS-i, 4A, integrated overload protection Integrated ground fault detection, signaling contact, remote reset
AS-i data decoupler 2x4A, screw terminals, AS-i dual, data decoupling module, IP20, SlimLine S22.5, screw terminals, overall width module 22.5 mm, input: 24-30 VDC, output: 2xAS-i, 4 A, integrated overload protection Integrated ground fault detection, signaling contact, remote reset
AS-i data decoupler 1x4A, spring-type terminals, AS-i single, data decoupling module, IP20, SlimLine S22.5, spring-type terminals, overall width module 22.5 mm, Input: 24-30 VDC, output: 1xAS-i, 4A, integrated overload protection Integrated ground fault detection, signaling contact, remote reset
AS-i data decoupler 2x4A, spring-type terminals, AS-i dual, data decoupling module, IP20, SlimLine S22.5, spring-type terminals, overall width module 22.5 mm, Input: 24-30 VDC, output: 2xAS-i, 4A, integrated overload protection Integrated ground fault detection, signaling contact, remote reset
Simatic S7-1200, DCM 1271, data decoupling module for AS-i Master CM 1243-2, input: 24-30 VDC, output: 1xAS-Interface, 4A, integrated overload protection Integrated ground fault detection, signaling contact
Sitop UPS500S, maintenance free uninterruptible, power supply with USB interface, basic device 2.5 kWs, input: 24 VDC, output: 24 VDC/15A, degree of protection IP20
Sitop UPS500S, maintenance free uninterruptible, power supply with USB interface, basic device 5 kWs, input: 24 VDC, output: 24 VDC/15A, degree of protection IP20
Sitop UPS501S, expansion module 5 kWs for UPS500S (2.5 kWs, 5 kWs) degree of protection IP20
Sitop UPS1600 10A, uninterrupted power supply, input: 24 VDC, output: 24 VDC/10A
Sitop UPS1600 10A, USB uninterrupted power supply with USB interface, input: 24 VDC, output: 24 VDC/10A
Sitop UPS1600 10A, Ethernet/Profinet uninterrupted power supply with Ethernet/Profinet interface/OPC UA Server/Web server, input: 24 VDC, output: 24 VDC/10A