FUS080 sparepart transmitter for SONOKIT sys.7ME321&322 Type SITRANS FUS080 IP67 Polyamide, Supply: 115-230V AC, 3.6V BU (The original system number and system serial number must be specified on order).
FUS080 sparepart transmitter for SONOKIT sys.7ME321&322 Type SITRANS FUS080 IP67 Polyamide Supply: 3.6V, No Battery (The original system number and system serial number must be specified on order).
SITRANS FUS SONO 3300/FUS060 2-track ultrasonic In-Line flowmeter, diameter DN 50 to DN 300 (2" to 12"). Suitable for volume flow measurement of liquids, for applications in water and treated wastewater, oil and liquefied gases, hot water/cooling systems.
SITRANS FUS SONO 3100/FUS060 2-track ultrasonic In-Line flowmeter, diameter DN 100 to DN 1200 (4" to 48"). Suitable for volume flow measurement of liquids, for applications in water and treated wastewater, oil and liquefied gases, liquidcryogenic application, district heating systems.
SITRANS FUS SONO-KIT 1-Track Retrofittable ultrasonic In-Line flowmeter, diameter DN 100 to DN 2400 (4'' to 96''). Suitable for volume flow measurement of liquids, for applications in raw water for water treatment plants, water distribution systems, power generation, district heating plants.
SITRANS FUS SONO-KIT 2-Track Retrofittable ultrasonic In-Line flowmeter, diameter DN 200 to DN 3000 (8" to 120"). Suitable for volume flow measurement of liquids, for applications in raw water for water treatment plants, water distribution systems, power generation, district heating plants.
SITRANS FUS380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"). Suitable for volume flow measurement of liquids, for applications in district heating plants, local networks, boiler stations, chiller plants and water applications.
SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants.
SITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants.
Non Ex Ch2: Current/Freq./Pulse, Ch3: None Ch4: None. Terminal Select Active/Passive.
Non Ex Ch2: Current/Freq./Pulse, Ch3: Current/Freq./Pulse Ch4: None. Terminal Select Active/Passive.
Non Ex Ch2:Current/Freq./Pulse, Ch3:Current/Freq./Pulse Ch4:Current/Freq./Pulse. Terminal Select Active/Passive.
Non Ex Ch2:Current/Freq./Pulse, Ch3: Current/Freq./Pulse Ch4: Relay. Terminal Select Active/Passive.
Non Ex Ch2: Current/Freq./Pulse, Ch3: Relay Ch4: Relay. Terminal Select Active/Passive.
Non Ex Ch2: Current/Freq./Pulse, Ch3: Relay Ch4: None. Terminal Select Active/Passive.
I/O cassette F11, Ex - Passive, Ch2: Current/Frequency/Pulse, Ch3: None, Ch4: None Mandatory requirements: Complete MLFB and serial number of original unit and whether it is for coriolis or clamp on.
I/O cassette F12, Ex - Passive, Ch2: Current/Frequency/Pulse, Ch3: Current/Frequency/Pulse, Ch4: None.
I/O cassette F13, Ex - Passive, Ch2: Current/Frequency/Pulse, Ch3: Current/Frequency/Pulse, Ch4: Current/Frequency/Pulse.
I/O cassette F14, Ex - Passive, Ch2: Current/Frequency/Pulse, Ch3: Current/Frequency/Pulse, Ch4: Relay.